LPWA Module Series
BG95 Hardware Design
BG95_Hardware_Design 65 / 80
6.3. Operation and Storage Temperatures
The operation and storage temperatures of the module are listed in the following table.
Table 34: Operation and Storage Temperatures
1.
1)
Within operation temperature range, the module is 3GPP compliant.
2.
2)
Within extended temperature range, the module remains the ability to establish and maintain a
voice, SMS, data transmission, emergency call, etc. There is no unrecoverable malfunction. There
are also no effects on radio spectrum and no harm to radio network. Only one or more parameters
like Pout might reduce in their value and exceed the specified tolerances. When the temperature
returns to the normal operating temperature levels, the module will meet 3GPP specifications again.
6.4. RF Output Power
The following table shows the RF output power of BG95.
current (during
transmission slot)
control level on
EGSM900
USB_VBUS USB detection
BG95-M1/
BG95-M2/
BG95-N1/
BG95-M3
3.0 5.0 5.25 V
Parameter Min. Typ. Max. Unit
Operation Temperature Range
1)
-35 +25 +75 ºC
Extended Temperature Range
2)
-40 +85 ºC
Storage Temperature Range -40 +90 ºC
NOTES