RADWIN5000ConfigurationGuide Release4.9.17 7‐5
SoftwareUpgradeavailable MonitoringandDiagnostics
Figure7‐4:ThisHSUrequiresasoftwareupgrade
OntheHSUwindow,thesemessagesappearasshowninFigure 7‐4.
Themessagesareasfollows:
7.3.1SoftwareUpgradeavailable
Thisisanadvisorymessage. Iftheupgradeisnotcarriedout,thencorrectionsintheupgrade
willnotbeavailable.ThismessagemayappearforanactiveHBSoranyHSUinthesector,
registeredornot.
7.3.2SoftwareUpgraderecommended
Thisisalsoanadvisorymessage.IttypicallyoccurswithanewHBSornewHSUsaddedtoa
sector.
Iftheupgradeisnotcarriedout,thentheHBSorHSU(s)willoperatewithlimitedor
degradedfunctionality.ThismessagemayappearforanactiveHBSoranyHSUinthesector,
registeredornot.
7.3.3SoftwareUpgraderequired
ThismessagewillbedisplayedifaproductbandIDmismatchisdetected.
ThusforaHBS,itcannotoccurunlessoneormoreHSUsareregistered.AffectedHSUswill
alwaysshowitasdepictedaboveinFigure 7‐4above.
ForsuchHSUs,trafficisdisabledandtheonlyservicesavailableareChangeBandand
SoftwareUpgrade.
7.4ThroughputChecking
Inthismode,RADWIN5000HPMPestimatesEthernetthroughputperlink.