RADWIN5000ConfigurationGuide Release4.9.17 7‐15
RADWINManagerTraps MonitoringandDiagnostics
TSLThreshold
Acounterismaintained,ofthenumberofsecondintervalsduringwhichTxpowerexceeds
thisthreshold.
BBERThreshold
TheBackgroundBlockErrorRatioismeasuredasapercentage.Thethresholdcanbesetfrom
0.1%upto50%.
An8%thresholdisrecommended.Iftherearenoproblemsduringtheinterval,thenforthat
threshold,therecommendedBBERvalueshouldbe0.Sincethesystemprovidesalossless
Ethernetservice,thereisthroughputdegradationincaseofinterference.Thedegradationis
proportionaltotheBBER.
EthernetThresholds‐Capacity
ThisisusedasabasisforcheckingadherencetoaServiceLevelAgreement.Itisthenumber
ofsecondscountthatthelinkcapacityfallsbellowthethreshold.
EthernetThresholds‐Tr affic
Thenumberofsecondscountthatreceivedtrafficex ceededthisthreshold.Itcanbeusedto
measuretrafficpeaks.
7.7RADWINManagerTraps
TheRADWINManagerapplicationissuestrapstoindicatevariousevents,displayedinthe
EventsLog.
Table7‐4:RADWINManagerTrapMessages
TrapMessage Severity Remarks
Cannotbindtotrapserviceport.Port
162alreadyinusebyProcessName(pid:
ProcessId)
Warning
RADWINManagerwillnotcatchany
trapsfromtheODU,someother
applicationhasgrabbedthisport.
Deviceunreachable! Error CheckconnectivitytoODU
Connectedto<site_name> Information
<site_name>Sitewillbereset. Information
RestoreFactoryDefaultSettingsin
processonSite<sit
e_name>
Information
FactorySettings:Theprocesswasnot
finishedduetoconnectionissues.
Warning
Factorysettingfailedduetoconnectivity
problemtoODU
Reset:Theprocesswasnotfinisheddue
toconnectionissues.
Warning
Factorysettingfailedduetoconnectivity
problemtotarget‐ODUwillnotbe
reset
CannotWritetoMonitorfile.Thereis
notenoughsp
aceonthedisk.
Warning
Freesomespaceondiskonthe
managingcomputerandretry