15
6.3 Push-Button Control Station Connection
WARNING
• Wall controls must be mounted in clear view of the door, far enough from the door, or positioned such
that the user is prevented from coming in contact with the door while operating the controls and at least
5 feet (1.5 m) above the standing surface.
Figure 7 - 3-Push Button Control Station
Open / Close / Stop
6.4 Monitored External Entrapment Protection Device Connection
NOTICE
• Do NOT connect more than one (1) monitored entrapment protection device simultaneously on the
MONIT terminals without the use of an interface module, refer to section Error: Reference source not
found.
• Photoelectric cells must be installed facing each other across the door's path within 6” (15 cm) of the
plane of the door and the beam no more than 5-3/4” (14.6 cm) above the floor.
• If a non-monitored photoelectric cell, pneumatic sensing edge or electric sensing edge is used instead of
a monitored entrapment protection device, the operator will ONLY function in C2 (constant-pressure-to-
close) mode. Radio or open/close controls will only open the door.
6.4.1 Monitored Photoelectric Cell
Series 5000 By Vitector Fraba
Model HAE00056 By Linear Corporation
For technical support, please call 1-800-4-Raynor (1-800-472-9667) or visit www.raynor.com
Figure 8 - PHOTO Connection