3
Installation Instructions
IMPORTANT INSTALLATION INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF SEVERE INJURY OR
DEATH TO PERSONS:
1. READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS.
2. Install only on a properly operating and balanced door. A door that is operating
improperly could cause severe injury. Have qualified service personnel make repairs
to cables, spring assemblies and other hardware before installing the operator.
3. Remove all pull ropes and remove, or make inoperative, all locks (unless mechanically
and/or electrically interlocked to the power unit) connected to the door before
installing the operator.
4. Installation of this door operator must be done by a qualified installer.
5. Verify that the operator is correct for type, size of door and frequency of use per the
operator specifications.
6. Install the door operator at least 8 feet (2.44 m) or more above the floor. If the
operator must be installed less than 8 feet (2.44 m) above the floor, then exposed
moving parts must be protected by covers or guarding, provided by the operator
manufacturer.
7. Do not connect the door operator to the source of power until instructed to do so.
8. Locate the control station: (a) within sight of the door, and (b) at a minimum height of
5 feet (1.5 m) above floors, landings, steps or any other adjacent walking surface and
(c) away from all moving parts of the door.
9. Install the Entrapment Warning Placard next to the control station in a prominent
location.
10. For products having a manual release, instruct the end user on the operation of the
manual release.
11. If you have any questions about the safety of the door operating system, do not install
the operator, contact Raynor at 1-800-472-9667.
For The California Market:
For technical support, please call 1-800-4-Raynor (1-800-472-9667) or visit www.raynor.com