30
2 Quick Fix Instructions
Table 7 - Basic Troubleshooting Guide ~ from floor level
Symptom Possible Cause Fix Problem
Door doesn't respond
to any command
“Stop” button is stuck. (LED D9 is OFF) ➔ Press and release the “Stop”
button on the wall station several
times.
No power supply. (LED D2 is OFF) ➔ Verify the incoming power line
from the main breaker, making sure
it has not tripped or blown a fuse.
Door closes only on
constant pressure
Photo cells are not properly aligned or are
obstructed. (LED D4 is ON)
➔ Clear the obstruction or re-align
photo cells.
Loop is obstructed (presence of metal).
(LED D10 is ON)
➔ Clear the obstruction.
When pressing “Open”
button, door opens
~1-2 ft, then stops and
reverses
Mechanical door lock is engaged. ➔ Release the door lock.
Verify if the rubber seal at the bottom of the door
is frozen to the ground (winter time).
➔ Clear ice and free the rubber
seal at the bottom of the door.
Door doesn't respond
to any radio command
No power supply (transmitter light is OFF) ➔ Replace transmitter's battery.
Poor radio control range. ➔ Bring the radio transmitter closer
to the operator.
Photo cells are not properly aligned or are
obstructed. (LED D4 is ON)
➔ Clear the obstruction or re-align
photo cells.
Timer to Close doesn't
close the door
Timer to Close has been suspended accidentally
for ONE cycle.
➔ Timer to Close will return to
normal after door have been fully
closed. Refer to p.23 for further
details.
Timer to Close closes
the door after being
suspended
Timer to Close is reactivated accidentally. ➔ To suspend the Timer to Close,
close door completely. Then press
the “Stop” button 3 times and then
press the “Close” button 3 times.
Refer to p.23 for further details.
For technical support, please call 1-800-4-Raynor (1-800-472-9667) or visit www.raynor.com