25
Mid-Stop Timer (MD TM)
This feature allows the Timer to Close to be enabled/disabled at the Mid-Stop position.
MD TM Activation Select Switch MD TM Deactivation
1. Verify if the close limit switch is activated and
if the close LED is ON.
2. Set select switch on 6 = Md Tm.
3. Press the “Close” button.
4. Set select switch on run mode (4, or 5).
1. Verify if the close limit switch is activated
and if the close LED is ON.
2. Set select switch on 6 = Md Tm.
3. Press the “Stop” button.
4. Set select switch on run mode
Single-Button Control (SBC)
With this feature, it is possible to use a single-channel transmitter for a Commercial Application, as well as a Single-
Button Control (SBC). The SBC provides the user with the possibility to open, stop or close the door by using a
single-button radio transmitter (or a single push-button station).
SBC Activation
SBC Deactivation
1. Verify if the close limit switch is activated
and if the close LED is ON.
2. Set select switch on 9 = SBC.
3. Press the “Open” button.
4. Set select switch on run mode (1, 4, or 5).
1. Verify if the close limit switch is activated
and if the close LED is ON.
2. Set select switch on 9 = SBC.
3. Press the “Stop” button.
4. Set select switch on run mode
(0, 1, 2, 3, 4 or 5).
Universal Auxiliary Output Module (8 = WLF)
The universal auxiliary output module is sold separately. The module allows for the connection of external devices
such as: red and green warning lights (custom sequences available), air curtains, horns, locks, etc...
For technical support, please call 1-800-4-Raynor (1-800-472-9667) or visit www.raynor.com