Interrupt Flag Register
(Cont'd)
Program
Interrupt
Note:
If
the
interrupt
condition is one
of
the
four
program
interrupts,
the
corresponding
bit
in
the
Program
Mask
register
must
also be
set
to cause
an
interrupt.
The
Interrupt
Flag
register
is scanned on a
priority
basis
and
the
highest
priority
interrupts
are
serviced first.
Each
interrupt
condition is
assigned a specific weight which is
put
into
the
rightmost
eight
bits
of
General
register
No. 15
of
the
ini
tiated
state
( P 3
or
P 4). This
weight
can
be used by
the
program
to
enter
the
proper
interrupt
routine.
Note: The
rightmost
two bytes
of
General
register
No. 15
in
P
3
or
P
4
are
cleared
and
reloaded each time
an
interrupt
occurs.
Table 8 lists
the
priority,
the
Interrupt
Flag
register
position,
the
program
state
initiated,
and
the
weight
of
each
of
the
interrupt
conditions.
Table
8.
Interrupt Conditions
and
Priority
Flag
State
Priority
Interrupt Condition
*Bit
Initiated
Weight
1
Power
Failure
2
0
P
4
0
2
Machine Check
21
P
4
4
3
External
Signal No. 1
22
P
a
8
4
External
Signal No. 2
2
a
P
3
12
5
External
Signal
No. 3
24
P
a
16
6
External
Signal No. 4
25
P
a
20
7
External
Signal No. 5
2
6
P
a
24
8
External
Signal No. 6
27
P
a
28
9
Interval
Timer
2
8
P
a
32
10 Selecter Channel
No.1
2
9
P
a
36
11 Selector Channel No. 2
2
10
P
a
40
12
Selector Channel No. 3
211
P
a
44
13
Selector Channel No. 4
212
P
a
48
Not
used
Not
used
16
Multiplexor Channel
2
15
P
a
60
17
Elapsed
Time Cluck 2
16
P
a
64
18
Console
Interrupt
Request
217
P
a
68
19
Paging
Error
2
18
P
a
72
20
Paging
Queue 2
19
P
a
76
21
Supervisor
Call
Instruction
2
20
P
a
80
22
Privileged
Operation
221
P
a
84
23
Op-Code
Trap
222
P
3
88
24
Address
Error
(Protect,
2
2a
P
a
92
Addressing, Specification)
25
Data
Error
224
P
a
96
26
Exponent
Overflow
2
25
P
a
100
27
Divide
Error
2
26
P
a
104
28
Significant
Error**
227
P
a
108
29
Exponent
Underflow**
2
28
P
a
112
30
Decimal Overflow**
2
29
P
a
116
31
Fixed
Point
Overflow**
2
ao
P
a
120
32
Test
Mode
2
31
P
a
124
*
2
0
= The
rightmost
bit
in
the
Interrupt
Flag
register.
**
Note:
These
interrupt
conditions can be
masked
by
two
separate
masks.
The
first,
the
program
mask,
is a four-bit, non-privileged,
program
settable
mask,
that
22

Table of Contents

Other manuals for RCA Spectra 70

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the RCA Spectra 70 and is the answer not in the manual?

RCA Spectra 70 Specifications

General IconGeneral
BrandRCA
ModelSpectra 70
CategoryComputer Hardware
LanguageEnglish

Related product manuals