Page #71 background imageLoading...
Page #71 background image
71
www.renishaw.com
>15ms
E
3-state alarm
ACi, Ri and Ti interfaces.
Differentially transmitted signals forced open circuit for >15ms when alarm conditions valid.
(Ri and Ti alarm conditions same as differential line driven output. ACi alarm conditions: <40% signal or overspeed).
Alarm
1
Differential line driven output
Ri and Ti interfaces
1
Inverse signals not shown for clarity.
Interface model Alarm asserted when
Ri0004
<40% signal
Overspeed
Ri0008
Ri0020
Ri0040
Ri0100
<20% signal
>130% signal
Ri0200
Ri0400
Interface model Alarm asserted when
Ti
<20% signal
>135% signal
Overspeed