IKONIC Tankless Water Heater Service Manual
38
ERROR A011
EXPLANATION
Flame Not Detected From Flame Rod.
In the case of ignition failure, the water heater will at-
tempt ignition 10 times (Including the post purge every
3 times).
If no flame is detected, the water heater displays the
"A011" error code on the User Interface.
Diagnostic Check
Gas supply pressure
Gas lter
Air lter
Venting
Igniter rod
Flame rod
Gas air ratio valve
Solenoid valve (SV)
Check Method
Gas supply pressure
1. Check the gas supply pressure and regulator at the
gas connection of the water heater.
The correct gas pressures are below;
Natural Gas (NG); 4.0”-10.5” W.C
Liquid Propane (LP); 8.0”-13.0” W.C
2. While the static pressure is normal, the use of an-
other gas appliance may cause a possible drop to the
water heater. Therefore, it is required to check static
and dynamic gas pressure.
Static pressure: Gas pressure during standby
Dynamic pressure: Gas pressure at max combustion
Gas Filter
Check the gas lter at the gas connection of the water.
Ensure the lter is not blocked by some foreign sub-
stance.
If the gas lter is blocked by something, clean the gas
lter and remove the cause.
ERROR CODE DIAGNOSTICS

Table of Contents

Other manuals for Rheem IKONIC RTGH-SR84i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rheem IKONIC RTGH-SR84i and is the answer not in the manual?

Rheem IKONIC RTGH-SR84i Specifications

General IconGeneral
BrandRheem
ModelIKONIC RTGH-SR84i
CategoryWater Heater
LanguageEnglish

Related product manuals