HOW TO REMOVE COMPONENTS
IGNITER COIL
1. Remove the hook lm part of the Over Heat Limiter
(OHL).
2. Remove Igniter rod cover.
3. Remove igniter coil wire from igniter rod (left side).
4. Remove white Molex connector from igniter coil.
5. Remove the screw (pictured below) from the igniter
bracket.
Flame Rod
White Molex Connector
Igniter Rod
Screw