IKONIC Tankless Water Heater Service Manual
44
ERROR CODE DIAGNOSTICS
ERROR A018
EXPLANATION
Lime build-up inside the heat exchanger
To prevent permanent damage to the unit, the unit must
be drained and flushed. Flushing procedure may need to
be repeated for excessive lime and scale build up.
Before starting flushing process, go to SERVICE and set
"Flush Heater?" to YES. When flushing is completed re-
turn the "Flush Heater?" setting to NO.
Refer to the Use & Care manual provided with the water
heater for complete flushing instructions.
After flush procedure has been done, clear the alarm. Re-
fer to “Clearing Current Alarms”.
NOTE: Flushing instructions utilize a submersible utility
pump.
(Provided with the Rheem/Ruud Tankless Flush Kit -
RTG20124)
Flushing frequency is based on water conditions and
average usage and should be conducted annually or as
recommended by a professional.
5 - Gallon Bucket
Utility Pump
Drain Hose
(hot water)
Hot Water
Service Valve
Cold Water
Service Valve
Drain Hose
(cold water)

Table of Contents

Other manuals for Rheem IKONIC RTGH-SR84i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rheem IKONIC RTGH-SR84i and is the answer not in the manual?

Rheem IKONIC RTGH-SR84i Specifications

General IconGeneral
BrandRheem
ModelIKONIC RTGH-SR84i
CategoryWater Heater
LanguageEnglish

Related product manuals