49
ERROR A035
EXPLANATION
Improper thermistor connection
This tankless water heater has three thermistors (Inlet,
Outlet and Heat exchanger thermistor)
If one or more possibly has a poor connection or not con-
nected in proper location, the water heater displays the
“A035” error code on the Liquid Crystal Display (LCD) on
the User
Diagnostic Check
• Inlet thermistor
• Outlet thermistor
• Heat exchanger thermistor
• Exhaust Thermistor
ERROR CODE DIAGNOSTICS
Turn Power OFF
Remove & reinsert connector "I"
Unit had a loose connection.
Thermistors appear to be OK.
Unit had a loose connection.
Thermistors appear to be OK.
Remove and reinsert each thermistor molexes
connector. The color of each molexes are
below:
Inlet thermistor: White
Outlet thermistor: Black
Heat exchanger thermistor: Yellow
Exhaust Thermistor: Red/Black
Test ALL thermistor.
Follow instructions for:
A031-Error code
A032-Error code
A033-Error code
A036-Error code
Does A035 Error
code appear?
Does A035 Error
code appear?
Yes
No
No
Yes