IKONIC Tankless Water Heater Service Manual
85
HOW TO REMOVE COMPONENTS
ORIFICE PLATE (NAT/LP)
8. Place two (2) gaskets on the LP (or NAT) orice plate.
9. Install the LP (or NAT) orice plate on to the gas ori-
ce block, for use with LP (or NAT) gas.
NOTE: To ensure a leak free joint, verify that both
gaskets on the gas orice block are in place and are in
good condition, before attaching the LP (or NAT) orice
plate.
10. Use the 7/16” long screw removed at step 7 to se-
cure the orice plate to the gas orice block, DO NOT
use different screw type or length.
NOTE: Install the orice plate in the right orientation.