Appendix
Status Read Commands
The command is sent from PC to the projector with
the format below;
“CR” [Command] [CR]
Command: one character (refer to the command
table below.)
The projector decodes the command and returns the
'Character string' with the format below;
Format
Command Function
Return
value
Projector status
CR0 Status Read
00
Power On
80
Stand-by mode
40
Countdown
20
Cooling down
10
Power Malfunction
28
Cooling down at the temperature anomaly
24
Cooling down at Power Management mode
04
Power Management mode after Cooling down
21
Cooling down after the projector is turned off when the lamps
are out.
81
Stand-by mode after Cooling down when the lamps are out.
88
Stand-by mode after Cooling down at the temperature
anomaly.
2C
Cooling down when the projector is turned off by the shutter
management function.
8C
Stand-by mode after Cooling down by the shutter
management function.
CR6 Temperature Read %1 %2
%1 = Temperature at Sensor 1 (˚C)
%2 = Temperature at Sensor 2 (˚C)
(ex.) %1 = 12.3 (˚C), %2 = 23.4 (˚C)
--> The projector returns “ 12.3 23.4”.
(For each sensor, two digit and the tenth place numbers are
displayed with a space between each temperature.)
?
Communication failure
The tables on page 98 show the typical command lists for controlling the projector. Please consult your local
dealer for further information of other commands.

Table of Contents

Other manuals for Sanyo PLC-HF15000L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sanyo PLC-HF15000L and is the answer not in the manual?

Sanyo PLC-HF15000L Specifications

General IconGeneral
BrandSanyo
ModelPLC-HF15000L
CategoryProjector
LanguageEnglish

Related product manuals