10 Technical specifications
GTE6-xxx1xV GTE6-xxx2xV GTE6-xxx3xV
Sensing range 12 ... 250 mm 45 ... 700 mm 40 ... 760 mm
Sensing range max. 10 ... 300 mm
1)
30 ... 900 mm
1)
30 ... 900 mm
1)
Light spot diameter/distance 6 mm / 100 mm 8 mm / 100 mm 6 mm / 100 mm
Supply voltage V
S
DC 10 ... 30 V
2)
DC 10 ... 30 V
2)
DC 10 ... 30 V
2)
Output current I
max.
100 mA 100 mA 100 mA
Max. switching frequency 500 Hz
3)
500 Hz
3)
500 Hz
3)
Max. response time < 1.25 ms
4)
< 1.25 ms
4)
< 1.25 ms
4)
Enclosure rating IP 67, IP 68, IP 69
K
5)
IP 67, IP 68, IP 69
K
5)
IP 67, IP 68, IP 69
K
5)
Protection class III
6)
III
6)
III
6)
Circuit protection A, B, D
7)
A, B, D
7)
A, B, D
7)
Ambient operating temperature -25 °C ... +55 °C -25 °C ... +55 °C -25 °C ... +55 °C
1)
Object with 90 % remission (based on standard white DIN 5033)
2)
Limit value; operation in short-circuit protection mains max. 8 A; residual ripple max. 5 V
ss
3)
With light / dark ratio 1:1
4)
Signal transit time with resistive load
5)
IP68: according to EN 60529 (water depth of 1 m / 24 h).
IP69K: according to ISO 20653:2013-03.
6)
Reference voltage DC 50 V
7)
A = U
V
-connections reverse polarity protected
B = inputs and output reverse-polarity protected
D = outputs overcurrent and short-circuit protected
TECHNICAL SPECIFICATIONS 10
8021850 | SICK
Subject to change without notice
11