Product description
24 © SICK AG · Germany · All rights reserved · Subject to change without notice 8013796/ZM63/2017-05-09
Operating Instructions
LMS5xx Laser Measurement Sensors
Chapter 3
Indicator lights
Further information see section 9.2 “Error displays of the indicator lights” on page 97.
7segment display
Used for diagnostics on occurring errors or malfunctions (see section 9.3 “Indications of the
7-segment display” on page 98).
3.7 Operating principle of the LMS5xx
The LMS5xx is a non-contact laser measurement sensor that scans the surrounding
perimeter radially on a single plane using pulses of light. The LMS5xx measures in two-
dimensional radial coordinates. If a laser beam emitted is reflected from a target object,
then the position of the object is given in the form of distance and angle. The LMS5xx can-
not see through objects during this process.
Fig. 5: Measuring principle of the LMS5xx
Scanning takes place in a sector of 190°. The scanning range of the LMS5xx is maximum
80 m on light, natural surfaces with an object remission > 100% (e.g. a white house wall).
See also section 10.2 “Operating range diagrams” on page 106.
Display Possible cause
Ù
LMS5xx measuring and no error reported
Ø
LMS5xx either not measuring (stopped by user) or measuring with error
events
Ð
Off: no contamination
On: contamination warning
Blinking: contamination error
Ú
At least one field is infringed (see section 3.10.3 “Operator for the
evaluation cases on the output” on page 43).
Û
Reserved
Tab. 11: Meaning of the indicator lights (LEDs)