Technical support
A.3 Notes on the use of third-party modules
SIMATIC IPC227G
Operating Instructions, 07/2022, A5E50059933-AC
93
failed" shows when you install
the operating system in the
M.2 NVMe/SATA SSD card and
The M.2 NVMe/SATA SSD card lost
the boot image or broken.
Reinstall the operating system or change another
M.2 NVMe/SATA SSD card.
The 1000M full duplex mode
cannot run at full speed on all
Time Coordinated Computing can
result in Giga Band Ethernet
Open firmware selection menu, select: "Setup Utility"
> "Power" > "Advanced CPU Control" > "C-States", and
change its value from "Enabled" to "Disable".
connection error while bridge
function is enabled.
Right-click the Windows Start menu and select
"Device Manager" > "Network adapters" > "Intel EC*
*GbE Connection" > "Properties" > "Advanced" >
"Promiscuous Mode", and change its value to
A.3 Notes on the use of third-party modules
crashes during
startup
• Redundant I/O addresses
• Redundant hardware interrupts
and/or DMA channels
• Fluctuation of signal frequencies
or levels
• Different pin assignment
Check your computer configuration:
• If the computer configuration corresponds to the delivery
state, contact your technical support team.
• If the configuration has changed, restore the factory state. To
do this, remove the third-party modules and restart the
device. If the error no longer occurs, the third-party module
being used was the cause of the fault. Replace the third-party
module with a Siemens module or contact the module
supplier.
If the device still crashes, contact your technical support team.
• Insufficient output of an external
power supply, e.g. UPS
• Use a higher capacity power supply
not start up or
switches off
immediately
• A counter voltage is fed into the
device by connected or installed
third-party components
Clarify the following with the supplier of the component:
• The component can be operated without an external power
supply.
• The component can be reconfigured so that it only uses the
external power supply or that of the device.