EasyManuals Logo
Home>Siemens>Controller>SIMOTION D410 Series

Siemens SIMOTION D410 Series User Manual

Siemens SIMOTION D410 Series
230 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #126 background imageLoading...
Page #126 background image
Commissioning (software)
4.10 Configuring drive-related I/Os (with symbolic assignment)
SIMOTION D410
126 Commissioning Manual, 02/2012
Procedure
The configuration of the I/Os is divided into two basic steps:
1. Configuring I/O terminals (Page 127)
The functionality of an I/O channel is configured
(e.g. configuration of a DI/DO as digital
output)
2. Configuring technology objects
and I/O variables (Page 129)
The access of technology objects and I/O variables to I/Os is configured.
The configuration is performed symbolically, whereby only "function-compatible" I/O
channels are offered for selection.
Example:
For the TO measuringInput, only symbolic assignments of the type MI (measuring input)
are offered for selection.
The required message frames and the interconnection are then set automatically by the
engineering system.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION D410 Series and is the answer not in the manual?

Siemens SIMOTION D410 Series Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION D410 Series
CategoryController
LanguageEnglish

Related product manuals