Diagnostics data
6.2 Diagnostic data and non-volatile SIMOTION data
SIMOTION D410
Commissioning Manual, 02/2012
207
The following points must be noted for the DIAGURLS.TXT file:
● A DIAGURLS.TXT file containing the standard IT DIAG sites is automatically created if
you have not stored your own DIAGURLS.TXT file.
● Standard IT DIAG sites are entered "without" a path specification (e.g. "devinfo.mcs" for
the standard IT DIAG site "devinfo.htm").
● Customized IT DIAG sites (such as "user.htm") in the \USER\SIMOTION\HMI\FILES
directory on the CompactFlash Card must contain the FILES/ path specification.
● If you have created subfolders (e.g. "myfolder" in the FILES directory), these must also
appear in the path.
● Only 1 file name may be used per line.
● Empty lines are not permitted (an empty line will be interpreted as the end of the list).
● No distinction is made between upper-case and lower-case letters.
● It does not matter whether you use "\" or "/" in the path name.
Figure 6-5 Depiction of DIAGURLS.TXT editor
6.2.4 Deleting/restoring non-volatile SIMOTION data
Prerequisite
The diagnostic data and non-volatile SIMOTION data has been backed up to the
CompactFlash Card, see section Backup of diagnostic data and non-volatile SIMOTION data
(Page 201).