Start-Up
4.7 Commissioning
4-88
SINUMERIK 802C
6FC5 597–3AA20–0BP2 (01.02)
2. Reset the access level.
To save the data which have been set during the start–up, an internal data saving is requi-
red. To this aim, set access level 7 (final customer); otherwise, access level 2 will also be
saved.
– Press the softkey Delete passw.
– The access level will be reset.
3. Carry out internal data saving.
– Press the softkey Save data.
4.7.5 Cycle start–up
Sequence of operations
When loading cycles into the control system, adhere to the following sequence of operations:
1. Save tool offset data and zero offsets either on the FLASH or on the PG (programming
device).
These data can be selected in the Services menu by pressing the Data outp./data...soft-
key.
2. Load all files of the selected technology path from the toolbox diskette into the control sy-
stem via the V24 interface.
3. Carry out POWER ON.
4. Reload the recovered data.