Start-Up
4.7 Commissioning
4-89
SINUMERIK 802C
6FC5 5973AA200BP2 (01.02)
4.8 Series machine start-up
Functionality
The objective of series machine start-up is:
S after commissioning, in order to bring another control system connected to the same ma-
chine type with minimum effort to the condition as after commissioning;
or
S under service conditions (after replacing hardware components), to bring a new control
system to the initial state with minimum effort.
Precondition
To carry out commissioning, a PC/PG provided with a V24 interface for data transfer from/to
the control system is necessary.
In the PC/PG, the PCIN tool must be used.
Sequence of operations
1. Create the series machine start-up file (transfer from the control system to the PC/PG).:
Make a V24 cable connection between the PC/PG (COM port) and the SINUMERIK
802S (X8).
Make the following settings in the WinPCIN tool:
Binary format
Receive data
Select the path where you want to save your data
Save
The PC/PG will set itself to Receive and will wait for data from the control system.
Enter the password for protection level 2 in the control system.
Call the Services/RS232 setting menu.
Select the Start-up data line from the Services menu and press Start data outp. to
output the series machine start-up file.
2. Reading in the series machine start-up file into the SINUMERIK 802S:
Enter the V24 interface settings as described under 1).
Press the Data In Start button in the Service menu. The control system is thus ready
to receive data.
Use the PCIN tool in the PC/PG to select the series start-up file from the DATA_OUT
menu and start data transfer.
The control system is brought to RESET with rebooting three times during and at the
end of data transfer. On completion of error-free data transfer, the control system is
completely configured and ready to operate.

Table of Contents

Other manuals for Siemens SINUMERIK 802C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 802C and is the answer not in the manual?

Siemens SINUMERIK 802C Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 802C
CategoryControl Systems
LanguageEnglish

Related product manuals