- 48 -
7.3 Return to origin parameter
The “Return to origin parameter” is the setting data for the return to origin operation.
Details of Return to origin parameter
Activation: “XX” = Become effective just after recorded into the driver,
“X” = Become effective after restarting the driver,
“-” = The parameter cannot be changed (fixed value).
Refer to “Appendix1.Defalt setting value per actuator”
Sets the direction of return to origin operation.
Even if “ORIG direction” is changed, direction of + to - of
step data is not changed.
●Default value ●Value changed from the default value
Electric actuator Electric actuator
The setting for the return to origin operation
pushing origin operation [Stop]
limit switch origin [Sensor]
A pushing force level at which to set the origin.
This is the fixed value for this driver.
(It should not be changed).
The allowable speed to move to origin.
The acceleration and deceleration during find origin.
This is the fixed value for this driver.
(It should not be changed).
The setting for ORIG sensor
The origin sensor is not effective.
[Disable]
The origin sensor is N.O type. [N.O].
The origin sensor is N.C type. [N.C.]
This is the fixed value for this driver.
(it should not be changed)
*1) The range varies depending on the electric actuator.
Please refer to the manual of the electric actuator for more details.
-200mm -100mm 0mm
(Origin)