Application exa
mples
Triggering on buses
Yo u can use your instrument to trigger on I
2
C, SPI, RS-232/422/485/UART, MIPI DSI-1, MIPI CSI-2, 8B/10B, USB , CAN, and
parallel buses. T he instrument can display both physical layer (as analog waveforms) and protocol level information (as
digital and symbolic waveforms).
NOTE. Some trigger types are not available on some instruments.
For detailed bus triggering procedures, use the following procedures: (See page 78, Triggering on a parallel bus.) and (See
page 80, Triggering on a serial bus.)
To set up the bus trigger:
1. Select Vertical > Bus Setup.
2. Select a bus type.
3. If you selected the Serial Bus Type,
select
the type of serial bus.
4. Specif
y the components.
5. Select
Trig > Bus Setup.
6. Select the bus you set up.
7. Select Trigger On to select the desired
tr
igger on feature.
170 MSO/DPO70000DX, MSO/DPO70000C, DPO7000C, and MSO /DP O5000 Series U ser Manual