3-12 SPG600 & SPG300 Sync Pulse Generators User Manual
HORIZONTAL. Use the left (
W) or right (X) arrow button to adjust the horizontal
offset. The value wraps around, so when the maximum value is reached the next
value is the minimum value. The range of the timing adjustment depends on the
selected video standard. Refer to Table 3-4 for the appropriate range.
FINE. This menu item is only available if Option 01 is installed. You can set the
value from -18.5 ns to +18.5 ns in 0.1 ns steps. Use the left (
W) or right (X) arrow
button to adjust the fine horizontal offset.
Timing (SDI) Submenu
This menu allows you to adjust the timing offset of the selected serial digital output
relative to the genlock signal or the internal reference signal. Use the up (
S) or
down (
T) arrow button to scroll through the menu. Figure 3-6 shows the Timing
(SDI) submenu diagram.
Figure 3-6: Timing (SDI) submenu diagram
VERTICAL. Use the left (
W) or right (X) arrow button to adjust the vertical offset.
The value wraps around, so when the maximum value is reached the next value is
the minimum value. The range of the timing adjustment depends on the selected
video standard. Refer to Table 3-5 for the appropriate range.
HORIZONTAL. Use the left (
W) or right (X) arrow button to adjust the horizontal
offset. The value wraps around, so when the maximum value is reached the next
value is the minimum value. The range of the timing adjustment depends on the
selected video standard. Refer to Table 3-5 for the appropriate range.
Table 3-4: Analog output timing range
Format name Vertical settings (line)
Horizontal settings (
µs)
NTSC -525 to +525 -63.5556 to + 63.5185
PAL -1250 to +1250 -63.9630 to +63.9630
Select TIMING (SDI) in the Video menu
Set the vertical timing in 1 line steps
Set the horizontal timing in 1 clock steps
TIMING : VERTICAL
0 Line (s)
TIMING : HORIZONTAL
0.0000
µsec

Table of Contents

Other manuals for Tektronix SPG3UP 01

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix SPG3UP 01 and is the answer not in the manual?

Tektronix SPG3UP 01 Specifications

General IconGeneral
BrandTektronix
ModelSPG3UP 01
CategoryPulse Generator
LanguageEnglish

Related product manuals