EasyManuals Logo
Home>Tektronix>Test Equipment>TBS2000 Series

Tektronix TBS2000 Series User Manual

Tektronix TBS2000 Series
328 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #243 background imageLoading...
Page #243 background image
Related commands
TRIGger:A:EDGE:SOUrce on page 226, TRIGger:A:EDGE:SLOpe on
page 225
Arguments
DC selects DC coupling, which passes all input signals to the trigger circuitry.
HFRej coupling attenuates the high-frequency components, above 50 kHz, of the
trigger signal.
LFRej coupling removes the low-frequency components, below 50 kHz, of the
trigger signal.
NOISErej selects DC low sensitivity, which provides stable triggering by
increasing the trigger hysteresis. Increased hysteresis reduces the trigger
sensitivity to noise but may require greater trigger signal amplitude.
Examples
TRIGger:A:EDGE:COUPlingDC sets the A edge trigger coupling to DC.
TRIGGER:A:EDGE:COUPLING? might
return :TRIGGER:A:EDGE:COUPLING DC indicating that the A edge trigger
coupling is set to DC.
TRIGger:A:EDGE:SLOpe
Sets or queries the slope for the A edge trigger. This is equivalent to setting the
Slope option in the Trigger menu.
Group
Trigger
Syntax
TRIGger:A:EDGE:SLOpe{RISe|FALL}
TRIGger:A:EDGE:SLOpe?
Related commands
TRIGger:A:EDGE:SOUrce on page 226, TRIGger:A:EDGE:COUPling on
page 224
T commands
TBS2000 Series Programmer 225

Table of Contents

Other manuals for Tektronix TBS2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TBS2000 Series and is the answer not in the manual?

Tektronix TBS2000 Series Specifications

General IconGeneral
BrandTektronix
ModelTBS2000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals