34
Spas with ThermOzone
ThermOzone accomplishes water sanitation by us-
ing a powerful oxidant, Ozone. This 100% organic
compound reacts with and destroys bacteria, mold,
fungus, etc. Through a proprietary process, ozone
effectiveness and air quality are maximized to pro-
vide optimal sanitation of your spa.
Components
A
Ozone Generator : Using Corona discharge
technology, the Ozone generator delivers 250
mg of Ozone per hour to the Mixing Vessel.
B
Mixing Vessel : Using Venturi action, the
Mixing Vessel pulls ozone from the Generator
and mixes it with Spa water fed from the
circulation pump. This is where the sanitation
occurs. An overow tube feeds unused ozone to the carbon lter but an internal valve keeps
water from entering the carbon lter. Treated water is sent back to the spa via the ozone jet.
C
Carbon Filter : Any excess ozone is passed through the Carbon Filter and is neutralized of
its oxidation effectiveness, releasing harmless oxygen underneath your cabinet.
D
Ozone Jet : A special laser jet provides a return back to the spa for the treated water.
Operation
In spas equipped with a circulation pump, the ThermOzone system is active any time the circula-
tion pump is running.
Chemical Usage
1. Spas that have ThermOzone installed should maintain a 1.0-3.0 ppm Chlorine level or a
1.0-3.0 ppm Bromine Level.
2. Depending on your usage, and if your water is clear, you can continue to reduce the amount
of chemicals you are using by trying to add sanitizer on a once weekly schedule, and
performing the rest of your weekly maintenance (Stain and Scale, Natural and Clear etc...)
on a bi-weekly basis.
Note: Chemicals must be maintained at a proper level. Take into consideration how often the
hot tub is used and the number users.
3. For ThermOzone to work more efciently, please remember to clean your lters bi-weekly.
Make sure you go no longer than one month between lter cleanings.
Note: If water becomes cloudy, please resume all chemical maintenance on a regular weekly
basis. If your usage increases, you may have to add an additional sanitizer treatment in the mid-
dle of the week.
AB C
D
Spas with ThermOzone

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ThermoSpas Designer Series and is the answer not in the manual?

ThermoSpas Designer Series Specifications

General IconGeneral
BrandThermoSpas
ModelDesigner Series
CategoryHot Tub
LanguageEnglish

Related product manuals