Page #10 background imageLoading...
Page #10 background image
2007.03.07Flow2 stairliftTab 04: Install, adjust and release
www.ThyssenKruppAccessibility.nl8
Preassembly
2.4 Fitting and installing the charging contacts
The charging contact is installed as follows:
1. Strip approximately 9 cm of the supply cable.
2. Attach a faston connector to the cable ends.
3. Feed the cables through the charging contact.
4. Secure the Faston connector on the lips in the charging contact.
5. Fit the charging contact to the rail with (2x) M6x16.
6. Adjust the position of the charging contact so that it is in line with the drive unit spring contact.
Adjustment is always necessary for a vertical start.
TIP
A rail section with a parking point will be fitted with an extra bracket with a feed-through
opening. The two-core supply cable must also be fed to this.
Fig. 2-6 Cable feed in charging contact
1
Fig. 2-7 Secure the cables
1
Fig. 2-8 Mount the charging contact on the rail
1
Fig. 2-9 Adjust the charging contact
1