E6581913
16
2) Error Processing (Binary mode)
In case an error occurs, communication error command (4EH(N) or 6EH(n)) and the error type
number is returned to the computer in addition to the checksum.
Omissible
(3.5bytes
Blank)
“/”
(2FH)
INV-NO
1 byte
Norn
(4EH)(6EH)
DATA
2 bytes
SUM
1 byte
(3.5bytes
Blank)
Checksum area Not omissible
“N” or “n” (1 byte) : Communication error command. Also for check during an inverter trip (includes standing
by for retrying and trip holding). “4EH (N)” is during normal condition, “6EH (n)” is during
trip.
DATA (2 bytes) : Error code (0004)
0004 : Checksum error (The checksum does not match)
No return : Command error, format error (specified number of bytes is not received in 1sec,
or parity error, overrun error or framing error), inverter number mismatch, and
inverter number other than 00H in broadcast communication.
Examples
Computer Inverter : 2F 58 02 05 C4 00 17 70 D8
Inverter Computer : 2F 4E 00 04 81 ... Checksum error
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Table of Contents

Other manuals for Toshiba TOSVERT VF-S15 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-S15 series and is the answer not in the manual?

Toshiba TOSVERT VF-S15 series Specifications

General IconGeneral
BrandToshiba
ModelTOSVERT VF-S15 series
CategoryInverter
LanguageEnglish

Related product manuals