Intake temperature
%
,
<
Grommet
Air cleaner
//
inlet hose
INTAKE TEMPERATURE SENSOR
REMOVAL
1. Hold the connector lock, and disconnect the connector.
2.
Remove the intake temperature sensor.
INSPECTION
INSTALLATION
Measure the resistance value between the terminals.
Firmly press the intake temperature sensor into the grommet
section of the air cleaner inlet hose.
Note:
After the installation, check
its
condition.
Make sure that it is firmly inserted and not installed at an
angle.
80 [I 761
0.32
Temperature
(OC)
[OF]
Resistance (kQ)
-20 [-41
16.2
20
[68]
2.45