[Point
111
Reassembly:
Align the notch in the yoke with the protruding section of the
magnetic switch.
STARTER MOTOR ASSY UNIT INSPECTION
Note:
Perform each test for a short time
(3
to
5
seconds).
1.
Pull-in test
Check that the pinion gear pops out when the ASSY is
connected as shown in the illustration.
2.
Holding coil holding test
From the pull-in test status, check that the pinion gear remains
popped out even after the C terminal wire is disconnected.
3. Plunge
'r return test
check that the pinion gear returns from the holding test status
of the holding coil when the terminal is disconnected as shown
in the illustration on the left.
4.
No-load test
(1)
Secure the starter motor with a vice.
(2)
During a no-load test, a large current will flow through the
lead wire, so use a thick lead wire.
(3) Read the ammeter once the display has settled.
Standard:
90
A
or less