I
I
i
I
IGNITION COIL
1
The ignition coil should be kept clean, particularly between the terminals, and the
:
terminal connections kept tight.
I
CONTACT BREAKER
UNIT-
Lubrication every
3,000
miles
(5,WO
krns.)
(i)
Remove the metal cover and lightly smear the face of the cam with one of
the greases recommended for the grease gun use in the "Recommended
Lubricants" chart in the Instruction Book.
If this
is
not available, clean
C
engine oil may be used.
1
I
WARNING
I
i
When carrying out the above lubrication, no oil or grease must be allowed to get
I
onto or near the contacts.
(ii) Lubricate the automatic timing control mechanism, using thin machine oil.
I
Fig.
70.
DISTRIBUTOR MODEL DKX2A
WITH
COVER
HEMOVED
i
171