EasyManuals Logo
Home>UNI-T>Test Equipment>UPO2000CS Series

UNI-T UPO2000CS Series User Manual

UNI-T UPO2000CS Series
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #31 background imageLoading...
Page #31 background image
UPO2000CS series User Manual
30
Slope
Rising Edge
Triggers when the input signal level at the rising edge is above
the set level
Falling Edge
Triggers when the input signal is at falling edge and voltage level
is higher than high trigger level.
Any Edge
Triggers when the input signal is at any edge and the voltage
level meet trigger setting.
Trigger
Setting
Enters trigger setting menu
Next Page Enters Beyond-range Trigger Menu (2)
Beyond-range Trigger Menu (2)
Functions Options Descriptions
Position
Enter Triggers when input signal enters trigger level range
Return Triggers when input signal leaves trigger level range
Time Triggers when time in trigger level mode matches set time
Trigger
Level
High The beyond-range high threshold level can be adjusted with the
LEVEL knob
Low The beyond-range low threshold level can be adjusted with the
LEVEL knob
Setting 8.0ns~10ns
Using the multipurpose knob to set the pulse width time to be
between 8.0ns~10.0s
Return Return to beyond-range trigger main menu
3.8 Delayed Trigger
To select delayed trigger mode, trigger source 1 and 2 need to be set. Trigger event occurs when the time between
the two trigger sources is met.
Note: Source edges 1 and 2 must be neighboring edges.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the UNI-T UPO2000CS Series and is the answer not in the manual?

UNI-T UPO2000CS Series Specifications

General IconGeneral
BrandUNI-T
ModelUPO2000CS Series
CategoryTest Equipment
LanguageEnglish

Related product manuals