Programable DC Electronic Load User Manual
25
modes. Through the set operation mode, the load is switched back and forth between the
two values.
Figure 4-2-1-1 Interface of Dynamic Mode
Parameters of dynamic mode:
Dynamic test Description of parameters
Mode Dynamic on-load mode: CC/CV
Operate mode
Continues: The load will automatically and
between two set high/low values till the operation reaches the set
repeating times, and then the test ends.
Pulse: Lower parameters will be on-loaded at first, and then the
load will switch to an upper value each time when it receives a
trigger signal, and it will switch back to the lower value at the end of
the set time. In pulse mode, lower timing is not necessary because
the reverse action will be triggered only once when one trigger
signal is received.
Reverse: Each trigger will lead to the switching of current on-load
status, and upper/lower timing is not necessary at this time.
Lower value Set the lower parameter value
Lower duration Set the lower on-loading time
Upper value Set the upper parameter value
Upper duration Set the upper on-loading time
Rise slope Set the rise slope
Fall slope Set the fall slope
Repeat Set the time of repetition cycles for an operation
For example, in the dynamic CC mode in the figure below, users set the lower and upper
current value, and the load will continuously switch the current value back and forth
between these two values.