Programable DC Electronic Load User Manual
35
the curve of battery discharge.
Figure 4-2-6-1 Interface of Battery Mode
Parameter setting in battery mode:
Parameter Description
Mode Battery discharge mode: CC/CR/CP
Load value Set loading value
Stop voltage Set the lower limit voltage of stopping discharge
In the battery mode, select any discharge mode as needed, and set the load parameters
and stop voltage of this mode. When the battery is discharged to the stop voltage, the
electronic load automatically stops loading.
Figure 4-2-6-2 Battery Mode
Description of battery mode:
In the actual test process, users can check the battery voltage, discharge current and
discharged capacity at any time. After the test, users can choose to display the discharge
curve for reference.
Operation steps:
1. In initial interface, select [Mode], [More], and then press [Battery] to enter the setting
Battery voltage
Stop voltage
CC battery discharge mode
Discharge time