Setting the cavity temperature or the Delta T value
The exact setting of the temperature inside the cavity ensures the food is cooked properly, both inside and
outside.
A lower temperature than the specified value dries the food out instead of cooking it.
A higher temperature than the specified value burns the surface while the core remains uncooked (sometimes
this is the desired result, especially where meat is concerned).
Cooking with the DELTA-T parameter is only possible during cooking steps which use the core probe to
control the cooking duration. By DELTA-T, we mean the difference between the temperature inside the oven
cavity and the value detected by the core probe inside the product.
The cavity temperature and Delta T parameters are mutually exclusive: if the cavity temperature is set, the
Delta T parameter is inoperable, and if the Delta T is set, the cavity temperature parameter is inoperable.
Setting the parameters
Caution!
Protect your arms and
hands - Risk of injury!
Always position the core probe as instructed.
Risk of damage!
Do not leave the probe hanging out of the
oven cavity.
Risk of damage!
Remove the probe from the food before
taking the pan or the dish out of the oven.
Risk of damage!