15
DS1083-048
AUX
ON DIP
4321 5
Main
ON DIP
4321 5
Secondary
ON DIP
4321 5
Secondary 0
ON DIP
4321 5
Secondary 1
ON DIP
4321 5
Door opener
free
ON DIP
4321 5
Door opener
privacy
ON DIP
4321 5
On
ON DIP
4321 5
Off
ON DIP
4321 5
Camera
lights
off
Station type
Secondary
station
address
Door opener
Interruption
Camera
lights
ON DIP
4321 5
Camera
lights
on
DOOR OPENING TIME The position of the rotary switch (DOOR TIME) determines the activation time of
the door lock.
Pos. 0 = 1 s Pos. 1 = 10 s Pos. 2 = 20 s Pos. 3 = 30 s
Pos. 4 = 40 s Pos. 5 = 50 s Pos. 6 = 60 s Pos. 7 = 70 s
Pos. 8 = 80 s Pos. 9 = 90 s
GUARANTEED CONVERSATION TIME The position of the rotary switch (CONV TIME) determines a
guaranteed conversation time, i.e. extends the busy time from the answer onwards.
The busy time is equal to the reply time (max. 60s) added to the guaranteed conversation time.
Pos. 0 = 1 s Pos. 1 = 10 s Pos. 2 = 20 s Pos. 3 = 30 s
Pos. 4 = 40 s Pos. 5 = 50 s Pos. 6 = 60 s Pos. 7 e 8 = 70 s
Pos. 9 = NOT ALLOWED
The guaranteed conversation time must be programmed in the same way for all system call stations.§