Connecting instructions for five-vein cable (three-phase appliances – 400/50/3):
A test start-up of the appliance is carried out by an appropriately trained
electrician who has also connected the machine so as to make sure that it is
properly connected (see the section on MAINTENANCE).
If the machine has been connected correctly, the mixer in the mixture-treating
cylinder will rotate anti - clockwise.
Should the mixers rotate in the wrong direction, it is necessary to change the
connecting position of any of the two phases.
Production cylinder mixer, installed in appliances with built-in inverter, will rotate
in the correct direction regardless of the connecting position of either of the
phases so it is necesary check the direction of the mixer in the cooking cylinder.
The mixer must rotate in clockwise direction.
Should the mixers rotate in the wrong direction, it is necessary to change the
connecting position of any of the two phases.
After connecting the appliance to the electricity network, appropriately trained
electrician must also control the power consumption. The current must not
exceed the maximum allowed on the identification plate or sticker (see the
section GENERAL FEATURES AND SPECIFICATIONS).
6 OPERATING THE APPLIANCE
The user operates the appliance standing in front of appliance. This position
allows user to handle the control panel, the safety switch and the water flow
regulation valve (shower).
The appliance must be always under users control during operation.
phase type color
L1 400 V ~ black
L2 400 V ~ brown
L3 400 V ~ grey
N neutral blue
PE ground yellow-green