38 HC 35 E • HC 45 E • HC 55 E
g
3.5 Technical data
HC 35 E HC 45 E
HC 45 E-SSP
HC 55 E HC 55 E-SSP
Voltage
230 V~, 50 Hz: ✲✲✲
400 V, 50 Hz, V3~: ✲✲
Fuse protection
16 A: ✲✲✲✲✲
Unit connection line
3 x 2.5 mm
2
– 6 m: ✲✲✲
5 x 2.5 mm
2
– 6 m: ✲✲
Capacity
3.1 kw: ✲✲✲
5.5 kw: ✲✲
Max. operating pressure
228 bar (22.8 MPa): ✲✲✲✲✲
Max. volume flow
5.5 l/min: ✲
6.6 l/min: ✲✲
10 l/min: ✲✲
Volume flow at 120 bar (12 MPa)
4.8 l/min: ✲
5.2 l/min: ✲✲
10 l/min: ✲✲
Max. size of tip with a spray gun
0.043 inch – 1.10 mm: ✲
0.052 inch – 1.30 mm: ✲✲
0.056 inch – 1.42 mm: ✲✲
Max. temperature ot the coating material
43° C: ✲✲✲✲✲
Max. Viscosity
40.000 mPa·s: ✲
50.000 mPa·s: ✲✲
65.000 mPa·s: ✲✲
Filter insert (standard equipment)
5 Maschen: ✲
0 Maschen: ✲✲✲✲
Weight
83 kg: ✲✲
84.5 kg: ✲
100 kg: ✲
103 kg: ✲
Hydraulic oil filling quantity
4.7 l ESSO Nuto H 32: ✲✲✲✲✲
Max. tire pressure
2 bar (0.2 MPa): ✲✲✲✲✲
Special high-pressure hose
DN 10 mm, 15 m, connection thread NPSM 3/8: ✲✲
DN 13 mm, 15 m, connection thread NPSM 1/2: ✲✲✲
DN 19 mm, 15 m, connection thread NPSM 3/4: ✲✲✲
Hose whip
DN 10 mm, 2.5 m, connection thread NPSM 3/8: ✲✲ ✲
Dimensions L x W x H
1160 x 955 x 655 mm: ✲
1185 x 955 x 655 mm: ✲✲
1200 x 955 x 655 mm: ✲✲
Max. sound pressure level
77 dB (A)* ✲
80 dB (A)* ✲✲
88 dB (A)* ✲✲
* Place of measurement: 1 m distance from unit and 1.60 m above reverberant floor, 120 bar (12 MPa) operating pressure.
Description of unit