Operating manual Manual Powder System SPRINT XE
5 Description
24 Order number 2354920 | Edition 01/2023
– Middle LED characteristic curve, medium
– Upper LED characteristic curve, steep
33 Illuminated display [Powder quantity]
– Lights up green
– Display range: 0–100%
– Resolution: 3.33%
– Single LED display: Set point (high voltage and powder are deactivated)
– Bar display: Actual value (high voltage and powder are activated)
34 Illuminated display [Total air volume]
– Lights up green
– Display range: 2–6m
3
/h
– Resolution: 0.2–0.5m
3
/h
– Single LED display: Set point (high voltage and powder are deactivated)
– Bar display: Actual value (high voltage and powder are activated)
35 Illuminated display: [Atomizing, ionizing and Tribo air volume]
– Lights up green
– Display range: 0.1–4m
3
/h
– Resolution: 0.1–1.0m
3
/h
– Single LED display: Set point (high voltage and powder are deactivated)
– Bar display: Actual value (high voltage and powder are activated)
36 Push button [Powder quantity]
– To activate the function, the powder quantity is set with control dial 24 and is indicated
in LED display 19.
– Adjusting range: 1–100%
– Resolution: 1%
37 LED display [Powder quantity]
– Lights up yellow, when the powder quantity is selected