Operating manual Manual Powder System SPRINT XE
7 Operation
36 Order number 2354920 | Edition 01/2023
7.3 FACTORY SETTING RECIPE NOS. 1–4
The following set values are stored in recipe Nos. 1–4 in the factory.
Recipe no. Designation Characteristic High voltage
[kV]
Current limitation
[µA]
Character-
istic
Total air
[m
3
/h]
Feed air
[%]
Atomizing air
[m
3
/h]
P01 Flat part High surface cov-
erage
90 80 Standard 4.0 70 0.1
P02 Second coat-
ing
Avoidance of
spraying back
50 20 Soft 3.6 57 0.1
P03 Profile part Penetration and
reduced build-up
of edges
70 40 Soft 3.6 50 0.1
P04 Double click Small components 80 20 Soft 3.6 45 0.1
P05–50 variable individual 80 100 Standard 4.5 80 0.1
Info
Under normal conditions, metallic powder can be processed well using recipes Nos.1–4.
When operating the system with a Tribo gun, the values for total air, powder feed and Tribo air must be adjusted accordingly and saved.
With the 3 L tank variant, the values must also be adjusted individually and saved.