Phaser 3600 Printer Service Manual 1-9
General Information
Electrical Specifications
Environmental Specification
Power Rating and Line Voltages
Characteristic Specification
Primary line voltages 110 - 127 V Printer - (100 - 135 V) 13 amp circuit
220 - 240 V Printer - (180 - 264 V) 7-8 amp circuit
Primary line voltage
freque
ncy range
100 - 135 V Printer - 50/60 Hz + 3 Hz
220 - 240 V Printer - 50/60 Hz
+ 3 Hz
Power consumption Printing: 550 Watts (average)
Sleep: under 10 Watts
Operating Environment
Characteristic Specification
Optimal Temperature 10 - 30 degrees C (50-60 degrees F)
Optimal Humidity 20% - 80% Relative Humidity
Altitude
Operating
Low Altitude Setting
High Altitude Setting
Transportation
0 - 2,500 meters (8,200 ft.)
0 - 2,050 meters (6,726 ft.)
2,050 - 2,500 meters (6,726 - 8,200 ft.)
0 - 6,092 meters (20,000 ft.)
Acoustic Noise
Idle
Printing
35.0db or less
49.0db or less
Acoustic Characteristic Mode Specification
Printing Simplex from Tray1 Less than 56.0 dBA
Simplex from MP Less than 56.0 dBA
Simplex from SCF Less than 59.0 dBA
Duplex from Tray1 Less than 59.0 dBA
Measurement Standby Less than 35.0 dBA
Warm up Less than 50.0 dBA
Maximum Less than 60.0 dBA