EasyManuals Logo
Home>Xinje>Servo Drives>DS5L1 Series

Xinje DS5L1 Series User Manual

Xinje DS5L1 Series
171 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #105 background imageLoading...
Page #105 background image
3. Press ENTER, panel display is iat--, servo is in enabled status right now;
4. Press INC or DEC, panel display is tune and flashing, enter auto-tuning status;
5. Driver will automatically send pulse instructions, if the auto-tuning is successful, the panel
shows done and flashing.
6. Press STA/ESC to exit internal instruction auto-tuning.
Note: In the process of auto-tuning, press STA/ESC will exit the auto-tuning operation and use the
gain parameters at the exit time. If auto-tuning fails, it is necessary to initialize the driver before
auto-tuning again.
Panel alarm in auto-tuning process
Error code
Meaning
Reasons
Err-1
Failure to search for optimal gain
Too large inertia ratio; too weak rigidity of
mechanism
Err-2
Overtrip alarm in auto-tuning process
Please make sure that there is no overrun
and alarm before auto-tuning.
Err-6
Driver is not in "bb" state at the time of
operation
Please make sure the present status of
driver
Err-7
Driver alarmed in auto-tuning process
The driver alarm occurs
XinJeServo software auto-tuning steps
1. click auto-tuning on the XinJeServo software main interface
2. set the auto-tuning trip in jog mode or manually