5.2.3 Rotation direction switching
Related parameter
Definition of rotation
direction
0- positive mode
1- negative mode
The user can change the rotation direction of servo motor through parameter P0-05. It is specified
that the "forward rotation" of the motor is "counter clockwise rotation" and "reverse rotation" is
"clockwise rotation". (all view from the motor axis)
5.2.4 Stop mode
Servo shutdown can be divided into inertia shutdown and deceleration shutdown according to the
shutdown mode. The following explains the servo shutdown mode.
The servo driver is not enabled, the servo motor
is not powered, and free deceleration to 0. The
deceleration time is affected by mechanical
inertia, equipment friction, etc.
The servo driver outputs the
reverse braking torque, and the
motor decelerates rapidly to 0.
Advantages: smooth deceleration, small
mechanical impact, small mechanical impact
Disadvantage: slow deceleration process
Advantages: short deceleration
time
Disadvantages: mechanical
impact
According to different scenarios of servo shutdown, it can be divided into servo off shutdown, alarm
shutdown and over travel shutdown.
(1) Servo OFF and alarm shutdown
Related parameter