EasyManuals Logo
Home>Xinje>Servo Drives>DS5L1 Series

Xinje DS5L1 Series User Manual

Xinje DS5L1 Series
171 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #76 background imageLoading...
Page #76 background image
Related parameter
Parameter
Meaning
Defaulted
setting
Unit
Range
Modify
Effective
P3-05
Internal speed 1
0
rpm
-9999+9999
Anytime
At once
P3-06
Internal speed 2
0
rpm
-9999+9999
Anytime
At once
P3-07
Internal speed 3
0
rpm
-9999+9999
Anytime
At once
Parameter
Signal
Default
setting
Range
Modify
Effective
P5-27
Internal
direction
/SPD-D
n.0000
Range: 0000-0014. Distribute to
input terminal through P5-27.
Anytime
At once
P5-28
Internal
speed
/SPD-A
n.0000
Range: 0000-0014. Distribute to
input terminal through P5-28.
P5-29
Internal
speed
/SPD-B
n.0000
Range: 0000-0014. Distribute to
input terminal through P5-29.
1. Correlation between running speed and terminal signal
Input signal
Running speed
SPD-DP5-27
SPD-AP5-28
SPD-BP5-29
0: forward run
0
0
Internal speed is zero
0
1
P3-05SPEED1
1
1
P3-06SPEED2
1
0
P3-07SPEED3
1: reverse run
0
0
Internal speed is zero
0
1
P3-05SPEED1
1
1
P3-06SPEED2
1
0
P3-07SPEED3
Note:
(1) /SPD-D signal is direction control, input SI terminal can be changed according to P5-27. The
validity of the terminal signal determines the direction of the motor.
(2) The combination of /SPD-A and /SPD-B input terminal effectiveness determines the multi
segment speed
M
Servo motor
Run the motor
at set speed
Servo unit
Speed selection
SPEED1 P3-05
SPEED2 P3-06
SPEED3 P3-07
User parameter
/SPD-D
/SPD-A
/SPD-B
Input
No need external speed or
pulse generator

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje DS5L1 Series and is the answer not in the manual?

Xinje DS5L1 Series Specifications

General IconGeneral
BrandXinje
ModelDS5L1 Series
CategoryServo Drives
LanguageEnglish

Related product manuals