VB5N series inverter
8
2. General Specification
Main Control
Function
Modulation mode
Optimized space voltage vector SVPWM modulation
Control mode
SVPWM control (dead zone compensation for optimized low-frequency)
Frequency precision
Digital Setting: max frequency × ±0. 01%;
Analog Setting: max frequency × ±0.2%
Frequency resolution
Digital Setting: 0.01Hz; Analog Setting: max frequency × 0.1%
Start frequency
0.40Hz ~ 20.00Hz
Torque boost
Auto torque boost, manual torque boost 0.1% ~ 30.0%
V/F curve
Five modes: constant torque V/F curve, 1 V/F curve mode by user and 3 kinds of
torque-derating modes (2nd power, 1.7th power, 1.2nd power)
Accelerate/Decelerate curve
Two modes: linear Acc/Dec, S curve Acc/Dec; seven kinds of Acc/Dec time,
Maximum: 6000 minutes, the time unit (minute or second) is selectable
DC brake
Initial frequency of DC braking: 0~15.00Hz
Braking time: 0~60.0 s
Braking current: 0~80%
Power consumption brake
Built-in brake unit, can connect external brake resistor
Jog
Range of jog frequendy: 0.1Hz~50.00Hz, Acc/Dec time of jog 0.1~60.0s
Built-in PI
Easy to form close loop control system
Multi-step speed running
Multi-step speed work through built-in PLC or control terminals
Textile wobble frequency
Adjustable preset frequency and center frequency
Auto voltage regulation
(AVR)
When the power system voltage changes, maintain the constant of output voltage
Auto energy saving running
Auto-optimize V/F curve according to the load condition to realize energy saving
operation
Auto current limit
Auto-limit running current to avoid trip caused by overcurrent
Fix-length control
The frequency inverter will stop running when reaching the fixed length
Communication
function
With RS485 port, support Modbus-RTU protocol. Be with master-slave mul-
ti-device linkage function
Operate function
Run Command channel
Operation panel setting; control terminals setting; serial port setting; three modes
are exchangeable
Frequency channel
Keyboard analog potentiometer setting; , keys setting; function code dig-
ital setting; serial port setting; UP/DOWN terminal setting; analog voltage setting;
analog current setting; pulse setting; combination setting; different setting modes
can be switched
Digital input channel
Forward/Reverse running command; 6 channels programmable digital input, can
set 35 kinds of function, X6 support 0~20KHz pulse input
Analog input channel
2 channels analog input , 4~20mA and 0~10V can be selected
Analog output channel
1 channel analog output: 0~10V/4~20mA, can output setting frequency, output
frequency
Digital/pulse output channel
1 channel programmable open-collector output; 1 channel relay output; 1 channel
0~20KHz pulse output
Operation panel
LED Display
Can display setting frequency, output voltage, output current and other parameters
External meter Display
Display output frequency, output current, output voltage and other physical quan-
tities
Button Lock
Lock all the buttons
Protection Function
Over current protection; over voltage protection; under voltage protection; over
heat protection; over load protection
Optional parts
Brake parts, operation panel, extension cable of operation panel