Page 16 DPA Series DPA80/DPA100 Operating Instructions
t
a
x
Connecting To Your Amplifier: Bridged (Mono) Operation
Pairs of channels may be independently bridged — channel pair 1+2, and/or channel pair 3+4.
The method is the same for both channel pairs:
Select the required bridged mode through the front panel MENU system (see page 43 for
more information).
Use Channel 1 or 3’s Output Speakon connector and connect as follows:
Pin 2+: Hot
Pin 1-: Cold
When operating in bridged mode, the minimum impedances are doubled.
The minimum load in bridged mode is 4 ohms.