Page 30 DPA Series DPA80/DPA100 Operating Instructions
t
a
x
Inp A PEQ:1
100Hz Q=3.0 10.0dB
Input Parametric EQ Bands 1 through 8
All parametric bands cover a frequency range of 19.7Hz to 32kHz when in standard PEQ mode.
Some restrictions apply when other filter types are selected. Move between frequency, ‘Q’
and filter gain by pressing ENTER.
PEQ Parametric EQ
LSF Low Shelf
HSF High Shelf
BPS Band Pass
NOT Notch
APF All Pass
PHF Phase
LPF Low Pass VariQ
HPF High Pass VariQ
LPF Low Pass Elliptical
HPF High Pass Elliptical
A filter must be in Bypass before its type can be changed. Once bypassed, the ENTER key will
allow access to the type list and this can be adjusted with the encoder, scrolling through the
types listed above.