VX-6R/E OPERATING MANUAL 83
MISCELLANEOUS SETTINGS
TRANSMITTER TIME-OUT TIMER
(
TOT
)
The TOT feature provides a safety switch which limits transmission time to a pre-pro-
grammed value. This will promote battery conservation by not allowing you to make exces-
sively-long transmissions, and in the event of a stuck PTT switch (perhaps if the radio or
a Speaker/Mic is wedged between car seats) it can prevent interference to other users as
well as battery depletion. As configured at the factory the TOT feature is set to 3 minutes,
and here is the procedure for activating it:
1. Press the
[
F/W
]
key, then press the
[
0
(
SET
)]
key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 67: TOT.
3. Press the
[
0
(
SET
)]
key momentarily to enable adjustment of this
Set Mode Item.
4. Rotate the DIAL knob to set the Time-Out Timer to the desired
“Maximum TX” time (1/3/5/10 minutes), or OFF.
5. When you have made your selection, press the PTT switch to
save the new setting and exit to normal operation.
1) When your transmission time is within 10 seconds of the Time-Out Timer
expiration, an Alert bell will provide an audible warning from the speaker.
2) Since brief transmissions are the mark of a good operator, try setting up
your radio’s TOT feature for a maximum transmission time of one minute. This will
significantly improve battery life, too!
CHANGING THE TX DEVIATION LEVEL
In many areas of the world, channel congestion has required that operating channels be
closely spaced. In such operating environments, it often is required that operators use
reduced deviation levels, so as to reduce the potential for interference to users on adjacent
channels. The VX-6R/E includes a simple method of accomplishing this:
1. Press the
[
F/W
]
key, then press the
[
0
(
SET
)]
key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 27: HLF.DEV.
3. Press the
[
0
(
SET
)]
key momentarily to enable adjustment of
this Set Mode Item.
4. Rotate the DIAL knob to set this Set Mode Item to “ON.” In this
configuration (HALF DEVIATION active), the transmitters de-
viation will be approximately ±2.5 kHz, and the received audio
output level will be increased, for easier listening on the narrow signal.
5. When you have made your selection, press the PTT switch to save the new setting
and exit to normal operation.
The “normal” setting for the deviation (when this Set Mode Item is set to
“OFF”) is ±5 kHz.

Table of Contents

Other manuals for Yaesu VX-6R

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yaesu VX-6R and is the answer not in the manual?

Yaesu VX-6R Specifications

General IconGeneral
Frequency Range (Transmit)144-148 MHz, 222-225 MHz, 430-450 MHz
Waterproof RatingIPX7
Antenna ConnectorSMA
Frequency Range (Receive)0.5-999 MHz
ModesFM
Channels/Memory900
DisplayLCD
Receiver TypeSuperheterodyne