<8. OPERATION VIA HART CONFIGURATION TOOL (HART 5)>
8-1
IM 01E30D01-01EN
8.
OPERATION VIA HART CONFIGURATION TOOL (HART 5)
ThisChapterdescribesthedevice(AXR)operation
proceduresusingaHARTcongurationTool(such
as FieldMate).
NOTE
For more details regarding the operations for
theHARTcongurationtool,readtheHART
congurationtooloperationsmanual.
Note: HART is a registered trademark of the
FieldComm Group.
8.1 HART Protocol Revision
For the models with the output signal code “-J”,
HART protocol revision 5 or 7 is selectable. The
protocolrevisionissetasspeciedintheorder.
Howtoconrmprotocolrevisionisshownbelow.
Therearetwowaystoconrmtheprotocolrevision
set to the transmitter.
(1)Conrmationbythenameplate
The HART protocol revision at the time of
shipment is shown by the last number at the
serial number column of the name plate.
F0801.ai
XXX…XX
5: HART 5
7: HART 7
(2) ConrmationbyusingHARTcongurationtool
Read Subsection 8.8.5.
IMPORTANT
Protocol revision supported by HART
congurationtoolmustbethesameorhigher
than that of the device.
Protcol revision
supported by HART
congurationtool
5 7
Protocol revision of
the device
5
7 ×
 : Communication OK
×: Communication NG
NOTE
In this User’s Manual, HART protocol revision
5 and 7 are described as HART 5 and HART 7
respectively.
NOTE
When the output signal code of the device is “-J”,
HART protocol revision can be changed. Read
Subsection 8.8.5 about the procedure of the
revision change of HART 5 and HART 7.
8.2 Device Description (DD) on
aHARTCongurationTool
and AXR Device Revision
8.2.1 DD Revision and Device Revision
BeforeusingtheHARTCongurationTool(such
asFieldMate),conrmthattheDD(Device
Description)oftheAXRisinstalledinthe
CongurationTool.
• AXR:HART5
• Devicetype:0x57
• DeviceRevision:2
• DDRevision:2
TheDDrevisionsforAXRandCongurationTool’s
canconrminaccordancewiththefollowingsteps.
If the correct DD is not installed in the HART
CongurationTool,downloadthemfromtheHART
ofcialsite,otherwise,contacttherespective
vendorsoftheCongurationToolforitsupgrade
information.
1. ConrmationofthedevicerevisionforAXR
(1) ConnecttheCongurationTooltotheAXR.
The device revision can be checked as
follows.
DD DeviceSetup→Review→Review4
→Flddevrev
2. Conrmationofthedevicerevisionforthe
HARTCongurationTool
(1) TurnonthepoweroftheCongurationTool
under the standalone condition.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA ADMAG AXR and is the answer not in the manual?

YOKOGAWA ADMAG AXR Specifications

General IconGeneral
BrandYOKOGAWA
ModelADMAG AXR
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals